MULTI DETECTOR Third
Description
<br><div style="max-height: 350px;"><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">Multi-Criteria Fire/CO Detector</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "> </span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">GENERAL DESCRIPTION</span></span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-PHOTO-T-W - TRIGA /TR-FIRE-CO-W and TR-FIRE-CO-IV are plug-in addressable<a style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif; color: rgba(var(--bs-link-color-rgb),var(--bs-link-opacity,1)); text-decoration-line: underline;"> devices</a> that provide both fire and carbon monoxide <a style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif; color: rgba(var(--bs-link-color-rgb),var(--bs-link-opacity,1)); text-decoration-line: underline;">(CO) detection</a>. The detector combines four separate sensing elements to sense multiple components of a fire: smoke, CO, light/flame, and heat. This approach enables enhanced sensitivity to real fire with heightened immunity to nuisance particulates. For CO, the detector’s electrochemical sensing cell creates a separate signal for life safety CO detection.</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">Multiple sensors and communication can greatly reduce nuisance alarms compared to single sensing methods. Sophisticated algorithms maximize the advantages of all four sensor types creating our best detection strategy offering heightened immunity to nuisance particulate and enhanced sensitivity to real fire.</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "> </span></p><p style="padding: 0px; margin: 0in 0in 0.0001pt; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify; text-indent: -0.25in;"><span style="padding: 0px; margin: 0px; font-family: Symbol;">·<span style="padding: 0px; margin: 0px; font-family: "> </span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">Photoelectric sensors detect airborne particles associated with smoke.</span></p><p style="padding: 0px; margin: 0in 0in 0.0001pt; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify; text-indent: -0.25in;"><span style="padding: 0px; margin: 0px; font-family: Symbol;">·<span style="padding: 0px; margin: 0px; font-family: "> </span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">Thermal sensors detect heat and rate-of-rise (135°F fixed temperature threshold).</span></p><p style="padding: 0px; margin: 0in 0in 0.0001pt; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify; text-indent: -0.25in;"><span style="padding: 0px; margin: 0px; font-family: Symbol;">·<span style="padding: 0px; margin: 0px; font-family: "> </span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">Infrared sensors discern light patterns in the environment as an additional data point for alarm determination.</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "> </span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">This ability to reject certain nuisance alarm triggers, such as theater smoke, supports the use of the fire/CO detector in applications where moderate to heavy nuisance conditions exist that might cause single sensing detectors to false alarm.</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "> </span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">Meets UL 268 7th edition and UL 521 listing requirements for fire detection and UL 2075 standard for system-connected life safety carbon monoxide detection.</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "> </span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">Released through the incomplete burning of various fuels, CO is a colorless, odorless and deadly gas that is virtually impossible to detect with the human senses. Because the<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">potential exists for dangerous levels of CO to accumulate in almost any building, legislation mandating the use of CO detection in commercial spaces continues to grow.</span></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-align: justify;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">TR-B200S series intelligent sounder bases are recommended for use with TR-FIRE-CO-W and TR-FIRE-CO-IV. These bases can generate either a Temp 3 pattern for fire or a Temp 4 pattern for CO alarm indication. The TR-B200S series bases recognize the Triga synchronization protocol for use as a component of the general evacuation signal – along with other Triga Audible/Visible devices – when connected to a power supply or Fire Alarm Control Panel (FACP) output capable of generating the System Sensor synchronization pulses.</span></p></div><br><div style="max-height: 350px;"><p style="padding: 0px; margin: 0in 0in 0.0001pt 0.25in; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-indent: -0.25in;"><span style="padding: 0px; margin: 0px; font-family: Symbol;">·<span style="padding: 0px; margin: 0px; font-family: "> </span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">Detects all four major elements of a fire</span></p><p style="padding: 0px; margin: 0in 0in 0.0001pt 0.25in; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-indent: -0.25in;"><span style="padding: 0px; margin: 0px; font-family: Symbol;">·<span style="padding: 0px; margin: 0px; font-family: "> </span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">Separate CO detection signal</span></p><p style="padding: 0px; margin: 0in 0in 0.0001pt 0.25in; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-indent: -0.25in;"><span style="padding: 0px; margin: 0px; font-family: Symbol;">·<span style="padding: 0px; margin: 0px; font-family: "> </span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">Separate audible signal for fire or CO alarm when used with a TR-B200S-series base</span></p><p style="padding: 0px; margin: 0in 0in 0.0001pt 0.25in; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-indent: -0.25in;"><span style="padding: 0px; margin: 0px; font-family: Symbol;">·<span style="padding: 0px; margin: 0px; font-family: "> </span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">Highest nuisance alarm immunity</span></p><p style="padding: 0px; margin: 0in 0in 0.0001pt 0.25in; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-indent: -0.25in;"><span style="padding: 0px; margin: 0px; font-family: Symbol;">·<span style="padding: 0px; margin: 0px; font-family: "> </span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">Automatic drift compensation for smoke and CO sensors</span></p><p style="padding: 0px; margin: 0in 0in 0.0001pt 0.25in; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-indent: -0.25in;"><span style="padding: 0px; margin: 0px; font-family: Symbol;">·<span style="padding: 0px; margin: 0px; font-family: "> </span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">RealTest® CO testing capability</span></p><p style="padding: 0px; margin: 0in 0in 0.0001pt 0.25in; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-indent: -0.25in;"><span style="padding: 0px; margin: 0px; font-family: Symbol;">·<span style="padding: 0px; margin: 0px; font-family: "> </span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">New modern profile with expanded color options</span></p><p style="padding: 0px; margin: 0in 0in 0.0001pt 0.25in; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-indent: -0.25in;"><span style="padding: 0px; margin: 0px; font-family: Symbol;">·<span style="padding: 0px; margin: 0px; font-family: "> </span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">Uses only one address on the SLC loop</span></p><p style="padding: 0px; margin: 0in 0in 0.0001pt 0.25in; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-indent: -0.25in;"><span style="padding: 0px; margin: 0px; font-family: Symbol;">·<span style="padding: 0px; margin: 0px; font-family: "> </span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">UL 268 7th edition, UL 521 and UL 2075 listed</span></p><p style="padding: 0px; margin: 0in 0in 0.0001pt 0.25in; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px; text-indent: -0.25in;"><span style="padding: 0px; margin: 0px; font-family: Symbol;">·<span style="padding: 0px; margin: 0px; font-family: "> </span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">10-year CO cell with end-of-life warning</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "> </span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">PHYSICAL/OPERATING</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Dimensions: Height: 2.7″ (69 mm) installed in TR-B200S series sounder base<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Diameter: 6.875″ (175 mm) installed in TR-B200S series sounder base<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Weight: 3.4 oz. (95 g)<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Operating Humidity Range: 15% to 90% Relative Humidity, Non-condensing<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Operating Temperature Range: 32°F to 100°F (0°C to 38°C)<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Air Velocity: 0 to 4000 ft./min. (0 to 1219.2 m/min.)</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "> </span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">ELECTRICAL SPECIFICATIONS</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Operating Voltage Range: 15 to 32 VDC<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Operating Current @ 24 VDC: 200 uA (one communication every 5 seconds with green LED blink on communication) Maximum Alarm Current: 2 mA @ 24 VDC (one communication every 5 seconds with red LED solid on)<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Maximum Current: 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED solid on)<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Isolator Load Rating: 0.0063</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "> </span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">CO MONITORING UL STANDARD REFERENCE</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Alarm thresholds (in parts per million) are as follows for:</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">70 ± 5ppm: Detector response time 60 – 240 min.<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">150 ± 5ppm: Detector response time 10 – 50 min.<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">400 ± 10ppm: Detector response time 4 – 15 min.</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "> </span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">STANDARDS</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Per UL standard 2075, the IDP-FIRE-CO-W and IDP-FIRE-CO-IV have been tested to the sensitivity limits defined in UL Standard 2034.<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">UL Standard: UL 268 7th Edition</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "> </span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">AGENCY LISTINGS AND APPROVALS</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">The listings and approvals below apply to the TR-FIRE-CO-W and TR-FIRE-CO-IV. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status.<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">UL Listed<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">FM approved</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "> </span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">ORDERING INFORMATION</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-FIRE-CO-W: Advanced multi-criteria fire/CO detector, bright white color.<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-FIRE-CO-IV: Advanced multi-criteria fire/CO detector, ivory color</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "> </span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">BASES</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-B501-WHITE: 4″ Mounting base, white<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-B501-IV: 4″ Mounting base, ivory<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-B501-BL: 4″ Mounting base, black<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-B300-6: 6″ Flanged mounting base, white TR-B300-6-IV: 6″ Flanged mounting base, ivory TR-B200S-WH: Intelligent addressable sounder base, white<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-B200S-IV: Intelligent addressable sounder base, ivory TR-B200S-LF-WH: Intelligent addressable sounder base, low-frequency, white<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-B200S-LF-IV: Intelligent addressable sounder base, low-frequency, ivory<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-B224BI-WH: Isolator base, white<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-B224BI-IV: Isolator base, ivory<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-B224RB-WH: Relay base, white<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-B224RB-IV: Relay base, ivory</span></p><p style="padding: 0px; margin-right: 0px; margin-bottom: 0.0001pt; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "> </span></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">ACCESSORIES</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-RA100Z: Remote LED annunciator</span></p></div><br>
