Jockey Pump Controllers

Home / Products / Fire Protection System / Jockey Pump Controllers

Jockey Pump Controllers

Description

<br><div style="max-height: 350px;"><p style="padding: 0px; margin: 11pt 0px; line-height: 1.38;"><span style="background-color: transparent; padding: 0px; margin: 0px; font-variant-numeric: normal; font-variant-east-asian: normal; vertical-align: baseline;"><span style="padding: 0px; margin: 0px;">Pacific Tech &amp; Engineering Ltd (PTEL)</span></span><span style="background-color: transparent; padding: 0px; margin: 0px; font-variant-numeric: normal; font-variant-east-asian: normal; vertical-align: baseline;"> provides Electric Motor Controllers for Jockey Pump are listed by Underwriters Laboratories (UL file number E309408) in accordance with UL508a (Standard for Industrial Control Panel), NFPA70 (National Electric Code) and relevant NEMA standard. Power ratings vary from 1.5 to 40 horsepower, 380 to 415 volts, 50 or 60 Hz. </span></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px;"><span style="padding: 0px; margin: 0px;"></span></p><p style="padding: 0px; margin: 11pt 0px; line-height: 1.38;"><span style="padding: 0px; margin: 0px; font-variant-numeric: normal; font-variant-east-asian: normal; vertical-align: baseline;">NAFFCO Electric Motor Controllers for Jockey Pump are listed by Underwriters Laboratories (UL file number E309408) in accordance with UL508a (Standard for Industrial Control Panel), NFPA70 (National Electric Code) and relevant NEMA standard. Power ratings vary from 1.5 to 40 horsepower, 380 to 415 volts, 50 or 60 Hz. </span></p></div><br><div style="max-height: 350px;"><table style="background-color: transparent; padding: 0px; margin-top: 0px; margin-right: 0px; margin-left: 0px; --bs-table-color: var(--bs-body-color); --bs-table-bg: var(--bs-body-bg); --bs-table-border-color: var(--bs-border-color); --bs-table-accent-bg: transparent; --bs-table-striped-color: var(--bs-body-color); --bs-table-striped-bg: rgba(0, 0, 0, 0.05); --bs-table-active-color: var(--bs-body-color); --bs-table-active-bg: rgba(0, 0, 0, 0.1); --bs-table-hover-color: var(--bs-body-color); --bs-table-hover-bg: rgba(0, 0, 0, 0.075); width: 668.078px; vertical-align: top; border-color: var(--bs-table-border-color);"><tbody style="padding: 0px; margin: 0px; vertical-align: inherit;"><tr style="padding: 0px; margin: 0px; border-width: var(--bs-border-width) 0;"><td style="padding: 0.5rem; margin: 0px; border-color: inherit; border-width: 0 var(--bs-border-width); box-shadow: inset 0 0 0 9999px var(--bs-table-bg-state,var(--bs-table-bg-type,var(--bs-table-accent-bg)));"><span style="padding: 0px; margin: 0px;">Power Rating</span></td><td style="padding: 0.5rem; margin: 0px; border-color: inherit; border-width: 0 var(--bs-border-width); box-shadow: inset 0 0 0 9999px var(--bs-table-bg-state,var(--bs-table-bg-type,var(--bs-table-accent-bg)));"><span style="padding: 0px; margin: 0px;">1.5 - 7.5 HP DOL Starter &amp; 10 - 40 HP Star Delta Starter</span><br style="padding: 0px; margin: 0px;"></td></tr><tr style="padding: 0px; margin: 0px; border-width: var(--bs-border-width) 0;"><td style="padding: 0.5rem; margin: 0px; border-color: inherit; border-width: 0 var(--bs-border-width); box-shadow: inset 0 0 0 9999px var(--bs-table-bg-state,var(--bs-table-bg-type,var(--bs-table-accent-bg)));"><span style="padding: 0px; margin: 0px;">Voltage</span><br style="padding: 0px; margin: 0px;"></td><td style="padding: 0.5rem; margin: 0px; border-color: inherit; border-width: 0 var(--bs-border-width); box-shadow: inset 0 0 0 9999px var(--bs-table-bg-state,var(--bs-table-bg-type,var(--bs-table-accent-bg)));"><span style="padding: 0px; margin: 0px;">230/380/415/480 V</span><br style="padding: 0px; margin: 0px;"></td></tr><tr style="padding: 0px; margin: 0px; border-width: var(--bs-border-width) 0;"><td style="padding: 0.5rem; margin: 0px; border-color: inherit; border-width: 0 var(--bs-border-width); box-shadow: inset 0 0 0 9999px var(--bs-table-bg-state,var(--bs-table-bg-type,var(--bs-table-accent-bg)));"><span style="padding: 0px; margin: 0px;">Frequency</span><br style="padding: 0px; margin: 0px;"></td><td style="padding: 0.5rem; margin: 0px; border-color: inherit; border-width: 0 var(--bs-border-width); box-shadow: inset 0 0 0 9999px var(--bs-table-bg-state,var(--bs-table-bg-type,var(--bs-table-accent-bg)));"><span style="padding: 0px; margin: 0px;">50/60 hz</span></td></tr></tbody></table><p style="padding: 0px; margin-right: 0px; margin-left: 0px;"><br style="padding: 0px; margin: 0px;"></p><p style="padding: 0px; margin: 11pt 0px; line-height: 1.38;"><span style="padding: 0px; margin: 0px; font-variant-numeric: normal; font-variant-east-asian: normal; vertical-align: baseline;"><span style="padding: 0px; margin: 0px;">FEATURES </span></span></p><p style="padding: 0px; margin: 11pt 0px; line-height: 1.38;"><span style="padding: 0px; margin: 0px; font-variant-numeric: normal; font-variant-east-asian: normal; vertical-align: baseline;">ENCLOSURE OPTIONS: NEMA 2, NEMA 3, NEMA 4, NEMA 4x, NEMA 12</span></p><p style="padding: 0px; margin: 11pt 0px; line-height: 1.38;"><span style="padding: 0px; margin: 0px; font-variant-numeric: normal; font-variant-east-asian: normal; vertical-align: baseline;"><span style="padding: 0px; margin: 0px;">STANDARD FEATURES</span></span><span style="background-color: transparent;"><br></span></p><ul><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;"><span style="background-color: transparent;">Main disconnect switch with rotary handle, sized for disconnecting motor horsepower and voltage. </span></li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Motor Starter (DOL) or Overload Relay (Star-Delta) rated to the motor's horsepower, with thermal and short circuit protection. </li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Rated motor connectors.</li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Circuit breaker for protection of control circuit and motor.</li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Star—Delta starting timer. (in Model NFY-JSD1 &amp; NFYJSD1-M1) </li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Power ON/Healthy indicator/free contact.</li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Pump Run indicator/free contact. </li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Pump Trip indicator/free contact.</li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Adjustable pressure switch.</li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Run Period Timer</li></ul><p style="padding: 0px; margin: 11pt 0px; line-height: 1.38;"><span style="padding: 0px; margin: 0px; font-variant-numeric: normal; font-variant-east-asian: normal; vertical-align: baseline;">MODELS: NFY-JDO1 Direct On-Line &amp; NFY-JSD1 Star-Delta.</span></p><p style="padding: 0px; margin: 11pt 0px; line-height: 1.38;"><span style="padding: 0px; margin: 0px; font-variant-numeric: normal; font-variant-east-asian: normal; vertical-align: baseline;">Selector switch for Hand-Off-Automatic Operation. </span></p><p style="padding: 0px; margin: 11pt 0px; line-height: 1.38;"><span style="padding: 0px; margin: 0px; font-variant-numeric: normal; font-variant-east-asian: normal; vertical-align: baseline;">NFY-JDO1-M1 Direct On-Line &amp; NFY-JSD1-M1 Star-Delta </span><span style="background-color: transparent;"><br></span></p><ul><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;"><span style="background-color: transparent;">Touch control panel to operate, monitor, and set up the controller.</span></li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Automatic and manual selection on the touch panel screen.</li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Real-time voltage and pressure reading on screen.</li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Real-time pump running status, alarm details, and time delay on screen.</li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Password protection.</li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Screen saver mode.</li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Up to 4 auxiliary inputs and 3 output ports. </li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Up to 5 predefined options to select on input auxiliary.</li><li style="padding: 0px; margin: 11pt 0px; line-height: 1.38;">Up to 24 predefined options to select on output auxiliary</li></ul></div><br>

Chat with us on WhatsApp!
Online

Hello, how can we help you?