Vertical Turbine Fire Pump
Description
<br><div style="max-height: 350px;"><p style="padding: 0px; margin: 0pt 0px; line-height: 1.38;">Vertical Turbine Fire Pump normally moves water from deep well or reservoir below ground level. It has a long vertical shaft connected to several impellers, and each additional impeller increases the amount of pump head.</p><p style="padding: 0px; margin: 0pt 0px; line-height: 1.38;"><br></p><p style="padding: 0px; margin: 0pt 0px; line-height: 1.38;">Pacific Tech & Engineering Ltd provide you NAFFCO made Vertical Turbine Fire Pump Set with a reliable solution for your firefighting pump needs by combining the stringent quality measures of UL, FM and NFPA standards with our proven experience in the fire protection field.</p><p style="padding: 0px; margin: 0pt 0px; line-height: 1.38;"><br></p><p style="padding: 0px; margin: 0pt 0px; line-height: 1.38;">We can offer you a complete package of services starting from engineering assistance to field start-up and periodic maintenance. Each pump set is tested in our NAFFCO factory, prior to dispatch, as per UL, FM and NFPA standards. These pumps are covered by a warranty of one-year subject to standard terms and conditions</p><p style="padding: 0px; margin-right: 0px; margin-left: 0px;"><br></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px;">RATINGS</p><p style="padding: 0px; margin: 0pt 0px; line-height: 1.38;"><span style="padding: 0px; margin: 0px; font-variant-numeric: normal; font-variant-east-asian: normal; vertical-align: baseline;">SERIES: NF-VT, PERFORMANCE RATINGS: COMPREHENSIVE RANGE</span></p><p style="padding: 0px; margin: 0pt 0px; line-height: 1.38;"><br style="padding: 0px; margin: 0px;"></p><table style="padding: 0px; margin-top: 0px; margin-right: 0px; margin-left: 0px; caption-side: bottom; --bs-table-color-type: initial; --bs-table-bg-type: initial; --bs-table-color-state: initial; --bs-table-bg-state: initial; --bs-table-color: var(--bs-body-color); --bs-table-bg: var(--bs-body-bg); --bs-table-border-color: var(--bs-border-color); --bs-table-accent-bg: transparent; --bs-table-striped-color: var(--bs-body-color); --bs-table-striped-bg: rgba(0, 0, 0, 0.05); --bs-table-active-color: var(--bs-body-color); --bs-table-active-bg: rgba(0, 0, 0, 0.1); --bs-table-hover-color: var(--bs-body-color); --bs-table-hover-bg: rgba(0, 0, 0, 0.075); width: 639.332px; vertical-align: top; border-color: var(--bs-table-border-color);"><tbody style="padding: 0px; margin: 0px; border-style: solid; border-width: 0px; vertical-align: inherit;"><tr style="padding: 0px; margin: 0px; border-style: solid; border-width: var(--bs-border-width) 0;"><td style="padding: 0.5rem; margin: 0px; border-color: inherit; border-width: 0 var(--bs-border-width); box-shadow: inset 0 0 0 9999px var(--bs-table-bg-state,var(--bs-table-bg-type,var(--bs-table-accent-bg)));">Flow Rate (Min. - Max.)<br style="padding: 0px; margin: 0px;"></td><td style="padding: 0.5rem; margin: 0px; border-color: inherit; border-width: 0 var(--bs-border-width); box-shadow: inset 0 0 0 9999px var(--bs-table-bg-state,var(--bs-table-bg-type,var(--bs-table-accent-bg)));">50 - 6000 US GPM**<br style="padding: 0px; margin: 0px;"></td></tr><tr style="padding: 0px; margin: 0px; border-style: solid; border-width: var(--bs-border-width) 0;"><td style="padding: 0.5rem; margin: 0px; border-color: inherit; border-width: 0 var(--bs-border-width); box-shadow: inset 0 0 0 9999px var(--bs-table-bg-state,var(--bs-table-bg-type,var(--bs-table-accent-bg)));">Pressure Ratings (Min. - Max.)<br style="padding: 0px; margin: 0px;"></td><td style="padding: 0.5rem; margin: 0px; border-color: inherit; border-width: 0 var(--bs-border-width); box-shadow: inset 0 0 0 9999px var(--bs-table-bg-state,var(--bs-table-bg-type,var(--bs-table-accent-bg)));">2.76 - 26 BAR**<br style="padding: 0px; margin: 0px;"></td></tr><tr style="padding: 0px; margin: 0px; border-style: solid; border-width: var(--bs-border-width) 0;"><td style="padding: 0.5rem; margin: 0px; border-color: inherit; border-width: 0 var(--bs-border-width); box-shadow: inset 0 0 0 9999px var(--bs-table-bg-state,var(--bs-table-bg-type,var(--bs-table-accent-bg)));">Speed Ratings (Min. - Max.)<br style="padding: 0px; margin: 0px;"></td><td style="padding: 0.5rem; margin: 0px; border-color: inherit; border-width: 0 var(--bs-border-width); box-shadow: inset 0 0 0 9999px var(--bs-table-bg-state,var(--bs-table-bg-type,var(--bs-table-accent-bg)));"><p style="padding: 0px; margin-right: 0px; margin-left: 0px;">1450 - 2950 RPM**</p></td></tr></tbody></table><p style="padding: 0px; margin: 0pt 0px; line-height: 1.38;"><br style="padding: 0px; margin: 0px;"></p><p style="padding: 0px; margin: 0pt 0px; line-height: 1.38;"><span style="padding: 0px; margin: 0px; font-variant-numeric: normal; font-variant-east-asian: normal; vertical-align: baseline;">* For Selected Capacities with optional material suitable for Sea Water Application is also available, contact the factory for more info.<br><br></span></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px;">** These values only indicate the overall range available in this series. For the availability of any specific ratings and details of its certification, please contact factory</p></div><br><div style="max-height: 350px;"><p style="padding: 0px; margin: 0pt 4pt 0pt 0px; line-height: 1.38;"><span style="padding: 0px; margin: 0px;"><span style="padding: 0px; margin: 0px; font-variant-numeric: normal; font-variant-east-asian: normal; vertical-align: baseline;">FEATURES</span><span style="padding: 0px; margin: 0px; font-variant-numeric: normal; font-variant-east-asian: normal; vertical-align: baseline;"> </span></span><span style="background-color: transparent;"><br></span></p><p style="padding: 0px; margin: 0pt 4pt 0pt 0px; line-height: 1.38;"><span style="background-color: transparent;"><br></span></p><p style="padding: 0px; margin: 0pt 4pt 0pt 0px; line-height: 1.38;"><span style="background-color: transparent;">Performance characteristics as per NFPA 20 </span><span style="background-color: transparent;"><br></span></p><p style="padding: 0px; margin: 0pt 4pt 0pt 0px; line-height: 1.38;"><span style="background-color: transparent;">Complete unit responsibility.</span><span style="background-color: transparent;"><br></span></p><p style="padding: 0px; margin: 0pt 4pt 0pt 0px; line-height: 1.38;"><span style="background-color: transparent;">Complete in-house fabrication capabilities.</span><span style="background-color: transparent;"><br></span></p><p style="padding: 0px; margin: 0pt 4pt 0pt 0px; line-height: 1.38;"><span style="background-color: transparent;">Hydrostatic testing facilities.</span><span style="background-color: transparent;"><br></span></p><p style="padding: 0px; margin: 0pt 4pt 0pt 0px; line-height: 1.38;"><span style="background-color: transparent;">Operation run test as per NFPA 20. </span><span style="background-color: transparent;"><br></span></p><p style="padding: 0px; margin: 0pt 4pt 0pt 0px; line-height: 1.38;"><span style="background-color: transparent;">Vertical Turbine models pumps for capacities up to 6000 USGPM.</span><span style="background-color: transparent;"><br></span></p><p style="padding: 0px; margin: 0pt 4pt 0pt 0px; line-height: 1.38;"><span style="background-color: transparent;">Drivers: Electric motor drive or diesel engine drive.</span><span style="background-color: transparent;"><br></span></p><p style="padding: 0px; margin: 0pt 4pt 0pt 0px; line-height: 1.38;"><span style="background-color: transparent;">Electrical testing capabilities for motors and controllers connected to fire pumps as per NFPA standards.</span><span style="background-color: transparent;"><br></span></p><p style="padding: 0px; margin: 0pt 4pt 0pt 0px; line-height: 1.38;"><span style="background-color: transparent;">Capable of supplying additional accessories wherever required.</span></p></div><br>